ISO 7 Cleanroom Certification

An ISO 7 cleanroom allows no more than 352,000 particles 0.5 µm and larger per cubic meter of air, plus 83,200 at 1 µm and 2,930 at 5 µm, under ISO 14644-1. Certification counts particles at set locations and usually adds HEPA leak, airflow and pressure tests. Compare ISO 7 certification quotes here.

Facilities anywhere in the U.S. can request quotes here.

ISO 7 particle limits (ISO 14644-1:2015)

Particle sizeMax particles per m³
≥0.5 µm352,000
≥1 µm83,200
≥5 µm2,930

Limits at 0.1, 0.2 and 0.3 µm don't apply to ISO 7. ISO 7 roughly matches "Class 10,000" in the cancelled US FED-STD-209E.

What ISO 7 certification includes

  • Particle counts at the minimum number of sampling locations from ISO 14644-1 Table A.1, in the agreed occupancy state (as-built, at-rest or operational)
  • Supporting tests from ISO 14644-3: installed HEPA filter leak, airflow volume and air change rate, pressure difference, airflow direction, recovery
  • Periodic reclassification: annually under ISO 14644-2 unless risk assessment and monitoring data support a longer interval

ISO 7 in sterile compounding (USP <797>)

Buffer rooms in a USP <797> cleanroom suite are ISO Class 7 or better. ISO 7 rooms need at least 30 total HEPA-filtered air changes per hour, and at least 0.020 in. water column positive pressure to the adjacent less-clean room. They're recertified at least every 6 months. See USP 797 certification.

Who needs it

  • Any facility with a room specified as ISO 7, for example a USP <797> buffer room, or a room your customer or quality system specifies as ISO 7
  • Rooms newly built, renovated or due for periodic classification

What to include in your quote request

  • Facility address
  • Number of ISO 7 rooms (and any ISO 5 or ISO 8 spaces) with area
  • Occupancy state to test
  • Number of HEPA filters
  • Standard you're working to (ISO 14644, USP <797>, customer spec)
  • Due date

Need quotes? Request quotes with one form →

Are you a certification or testing company? Join as a provider →

How getting quotes works here

  1. Send one request. Use the quote request form to describe your facility, where it is, the rooms or equipment, and the tests or standard you need.
  2. We share it with providers. Your request goes to certification and testing companies that cover your area and the type of work.
  3. Compare and choose. Providers that want the job send quotes. You compare scope and price side by side and pick who to hire, so you don't have to chase each company yourself.

Related

Requests are accepted nationwide. Browse locations.

FAQ

How many particles are allowed in an ISO 7 cleanroom?

Up to 352,000 particles 0.5 µm and larger per cubic meter, 83,200 at 1 µm, and 2,930 at 5 µm, per ISO 14644-1:2015.

Is ISO 7 the same as Class 10,000?

Roughly. "Class 10,000" comes from the cancelled US standard FED-STD-209E. ISO 14644-1 replaced it, and ISO 7 is the usual equivalent.

How many air changes does an ISO 7 room need?

ISO 14644 doesn't set an air change rate. USP <797> requires at least 30 HEPA-filtered ACPH for ISO 7 compounding rooms.

How often must an ISO 7 cleanroom be recertified?

ISO 14644-2 calls for annual periodic classification (extendable with risk assessment and data). USP <797> compounding rooms need recertification at least every 6 months.

What is the difference between ISO 7 and ISO 8?

ISO 8 allows 10 times more particles: 3,520,000 per m³ at 0.5 µm versus 352,000 for ISO 7.

Need quotes? Request quotes with one form →

Are you a certification or testing company? Join as a provider →