Laminar Flow Hood Certification Quotes

Laminar flow hood certification tests a clean bench or laminar airflow workbench (LAFW) for airflow velocity, HEPA filter leaks and air cleanliness. IEST-RP-CC002 is the recommended practice for these unidirectional-flow devices. When the hood is a USP <797> primary engineering control, it needs recertification at least every 6 months. Request multiple quotes here.

Facilities anywhere in the U.S. can request quotes here.

What laminar flow hood certification is

Laminar flow hoods (clean benches, LAFWs) blow HEPA-filtered air in one direction over the work surface, either horizontally or vertically, to protect the product. They don't protect the user from hazardous materials; use a biosafety cabinet or fume hood for that.

IEST-RP-CC002 (Unidirectional-Flow, Clean-Air Devices; current edition IEST-RP-CC002.5) covers performance evaluation and certification testing of these devices, including recertification of devices owned by the customer. Typical field tests include:

  • Airflow velocity at the filter face
  • HEPA/ULPA filter leak test: aerosol challenge and scan
  • Induction leak and backstreaming checks at the opening
  • Airflow visualization (smoke)
  • Where appropriate, lighting, noise and vibration

For pharmacy hoods, USP <797> adds total particle counts under dynamic conditions and a dynamic smoke pattern test.

Who needs it

  • Sterile compounding pharmacies: a LAFW used as a PEC must meet ISO Class 5 and be recertified at least every 6 months under USP <797>, including a dynamic smoke pattern test. Compounding aseptic isolators (CAIs) and compounding aseptic containment isolators (CACIs) are PECs too and follow the same 6-month cycle.
  • Labs and manufacturers using clean benches for contamination-sensitive work
  • Any hood that has been moved or had its filters replaced

What to include in your quote request

  • Facility address
  • Number of hoods by type: horizontal or vertical LAFW, CAI, CACI
  • Make, model and width if known
  • Whether any hood is a USP <797> PEC (so the 6-month CETA-based scope applies)
  • Tests needed: velocity, HEPA leak, particle count, smoke
  • Other equipment for the same visit
  • Due date and report requirements

Need quotes? Request quotes with one form →

Are you a certification or testing company? Join as a provider →

How getting quotes works here

  1. Send one request. Use the quote request form to describe your facility, where it is, the rooms or equipment, and the tests or standard you need.
  2. We share it with providers. Your request goes to certification and testing companies that cover your area and the type of work.
  3. Compare and choose. Providers that want the job send quotes. You compare scope and price side by side and pick who to hire, so you don't have to chase each company yourself.

Related services

Requests are accepted nationwide. Browse locations.

FAQ

How often does a laminar flow hood need certification?

If it's a USP <797> PEC, at least every 6 months and after relocation or replacement. Otherwise, IEST-RP-CC002 leaves recertification intervals to the customer, so follow your SOP, the manufacturer and any regulator.

Is a laminar flow hood the same as a biosafety cabinet?

No. A laminar flow hood protects the product only. A Class II biosafety cabinet also protects the user and environment, and is certified to NSF/ANSI 49.

What standard is used to test laminar flow hoods?

IEST-RP-CC002, Unidirectional-Flow, Clean-Air Devices. For pharmacy hoods, USP <797> also points certifiers to the CETA certification guide for sterile compounding facilities.

Are CAIs and CACIs certified the same way?

Under USP <797>, CAIs and CACIs are PECs, so they need ISO Class 5 certification and recertification at least every 6 months. List them in your request with make and model.

What ISO class does a compounding hood need?

ISO Class 5 or better under dynamic operating conditions.