ISO 8 Cleanroom Certification

An ISO 8 cleanroom allows no more than 3,520,000 particles 0.5 µm and larger per cubic meter of air, plus 832,000 at 1 µm and 29,300 at 5 µm, under ISO 14644-1. USP <797> ante-rooms must be ISO 8 or better. Certification adds HEPA leak, airflow and pressure tests. Compare ISO 8 quotes here.

Facilities anywhere in the U.S. can request quotes here.

ISO 8 particle limits (ISO 14644-1:2015)

Particle sizeMax particles per m³
≥0.5 µm3,520,000
≥1 µm832,000
≥5 µm29,300

ISO 8 roughly matches "Class 100,000" in the cancelled US FED-STD-209E.

What ISO 8 certification includes

  • Particle counts at the minimum sampling locations from ISO 14644-1 Table A.1, in the agreed occupancy state
  • Supporting tests from ISO 14644-3: installed HEPA filter leak, airflow and air change rate, pressure difference, recovery
  • Annual periodic classification under ISO 14644-2, extendable with risk assessment and monitoring data

ISO 8 in sterile compounding (USP <797>)

In a USP <797> cleanroom suite, the ante-room is ISO Class 8 or better. ISO 8 rooms need at least 20 total HEPA-filtered air changes per hour, and the ante-room must hold at least 0.020 in. water column positive pressure to the unclassified area. Recertification is at least every 6 months.

Who needs it

  • USP <797> ante-rooms and any room specified as ISO 8 by your customer or quality system
  • New, renovated or periodically reclassified rooms

What to include in your quote request

  • Facility address
  • Number of ISO 8 rooms (and connected ISO 7 or ISO 5 spaces) with area
  • Occupancy state to test
  • Number of HEPA filters
  • Standard (ISO 14644, USP <797>, customer spec)
  • Due date

Need quotes? Request quotes with one form →

Are you a certification or testing company? Join as a provider →

How getting quotes works here

  1. Send one request. Use the quote request form to describe your facility, where it is, the rooms or equipment, and the tests or standard you need.
  2. We share it with providers. Your request goes to certification and testing companies that cover your area and the type of work.
  3. Compare and choose. Providers that want the job send quotes. You compare scope and price side by side and pick who to hire, so you don't have to chase each company yourself.

Related

Requests are accepted nationwide. Browse locations.

FAQ

How many particles are allowed in an ISO 8 cleanroom?

Up to 3,520,000 particles 0.5 µm and larger per cubic meter, 832,000 at 1 µm, and 29,300 at 5 µm.

Is ISO 8 the same as Class 100,000?

Roughly. Class 100,000 comes from the cancelled US FED-STD-209E, which ISO 14644-1 replaced.

How many air changes does an ISO 8 room need?

ISO 14644 doesn't set one. For USP <797> compounding, ISO 8 rooms need at least 20 HEPA-filtered ACPH.

Does an ISO 8 ante-room need pressure monitoring?

Under USP <797>, classified rooms need a pressure differential monitoring system, and the ante-room must stay at least 0.020 in. water column positive to the unclassified area.

How often is ISO 8 recertified?

Annually under ISO 14644-2 (extendable with data), or at least every 6 months for USP <797> compounding rooms.

Need quotes? Request quotes with one form →

Are you a certification or testing company? Join as a provider →