USP 797 requirements explained

USP General Chapter <797> sets standards for compounding sterile preparations. Its current revision became official on November 1, 2023. Certification of classified areas, including each PEC, must be repeated at least every 6 months and includes airflow, HEPA filter integrity, total particle counts and a dynamic smoke pattern test. Need it done? Get quotes for USP 797 certification.

Facilities anywhere in the U.S. can request quotes here.

What USP <797> certification is

USP General Chapter <797> sets standards for compounding sterile preparations. Its current revision became official on November 1, 2023.

Before a compounding area is used, it must be certified with the CETA certification guide for sterile compounding facilities or an equivalent guideline. Certification of the classified areas, including the PEC, must then be repeated at least every 6 months and must include:

  • Airflow testing: air velocity and volume, air changes per hour, and the pressure differential between adjacent rooms
  • HEPA filter integrity testing: leak testing after installation and at each recertification
  • Total particle count testing under dynamic operating conditions
  • Dynamic airflow smoke pattern test for each PEC, showing unidirectional airflow sweeping away from the preparation

The PEC must meet ISO Class 5 under dynamic conditions, and it sits inside ISO Class 7 and 8 rooms (the secondary engineering controls, or SECs). Classified areas also need recertification after changes such as redesign, construction, replacing or relocating a PEC, or altering a room in a way that could affect airflow or air quality.

Viable air sampling (microbial) is separate from certification. USP <797> requires it at least every 6 months, and your certifier or other qualified people can do it.

Related pages

Requests are accepted nationwide. Browse locations.

FAQ

How often does USP 797 require recertification?

At least every 6 months for the classified areas, including each PEC. Recertify sooner after redesign, construction, replacing or relocating a PEC, or room changes that could affect airflow.

What tests are part of USP 797 certification?

Airflow testing (velocity, volume, air changes and pressure differential), HEPA filter integrity testing, total particle counts under dynamic conditions, and a dynamic smoke pattern test for each PEC.

What ISO class does a compounding hood need?

The PEC must meet ISO Class 5 or better under dynamic operating conditions.

Is viable air sampling part of certification?

They're different. Certification covers non-viable items like particle counts, airflow and pressure. Viable air sampling for bacteria and fungi is also required at least every 6 months, and you can add it to the same quote request.

Which certification guide do certifiers use?

USP <797> points to the current CETA certification guide for sterile compounding facilities, or an equivalent guideline.