USP 797 Cleanroom Certification Quotes

USP <797> requires sterile compounding areas, including each primary engineering control (PEC) such as a laminar airflow hood or BSC, to be certified before use and recertified at least every 6 months. Recertification covers airflow, HEPA filter integrity, total particle counts and smoke pattern tests. Send one request to compare quotes from providers.

Facilities anywhere in the U.S. can request quotes here.

What USP <797> certification is

USP General Chapter <797> sets standards for compounding sterile preparations. Its current revision became official on November 1, 2023.

Before a compounding area is used, it must be certified with the CETA certification guide for sterile compounding facilities or an equivalent guideline. Certification of the classified areas, including the PEC, must then be repeated at least every 6 months and must include:

  • Airflow testing: air velocity and volume, air changes per hour, and the pressure differential between adjacent rooms
  • HEPA filter integrity testing: leak testing after installation and at each recertification
  • Total particle count testing under dynamic operating conditions
  • Dynamic airflow smoke pattern test for each PEC, showing unidirectional airflow sweeping away from the preparation

The PEC must meet ISO Class 5 under dynamic conditions, and it sits inside ISO Class 7 and 8 rooms (the secondary engineering controls, or SECs). Classified areas also need recertification after changes such as redesign, construction, replacing or relocating a PEC, or altering a room in a way that could affect airflow or air quality.

Viable air sampling (microbial) is separate from certification. USP <797> requires it at least every 6 months, and your certifier or other qualified people can do it.

Learn more: USP 797 explained

Who needs it

  • Hospital, retail and outsourcing pharmacies, and any other facility that compounds sterile preparations
  • Sites with laminar airflow workbenches, biological safety cabinets, or compounding aseptic isolators used as PECs
  • Facilities handling hazardous drugs, which also need USP 800 certification

What to include in your quote request

  • Facility address and type (hospital, retail, 503B, clinic)
  • Number of PECs by type (LAFW, BSC, CAI, CACI, isolator), with make and model if known
  • Rooms and their ISO class: buffer room, ante-room, segregated compounding area
  • Whether any room is negative pressure for hazardous drugs (USP <800>)
  • Whether you also want viable air and surface sampling quoted
  • Date of your last certification and your due date
  • Report requirements (CETA guide, state board of pharmacy, accreditor)

Need quotes? Request quotes with one form →

Are you a certification or testing company? Join as a provider →

How getting quotes works here

  1. Send one request. Use the quote request form to describe your facility, where it is, the rooms or equipment, and the tests or standard you need.
  2. We share it with providers. Your request goes to certification and testing companies that cover your area and the type of work.
  3. Compare and choose. Providers that want the job send quotes. You compare scope and price side by side and pick who to hire, so you don't have to chase each company yourself.

Related services

Requests are accepted nationwide. Browse locations.

FAQ

How often does USP 797 require recertification?

At least every 6 months for the classified areas, including each PEC. Recertify sooner after redesign, construction, replacing or relocating a PEC, or room changes that could affect airflow.

What tests are part of USP 797 certification?

Airflow testing (velocity, volume, air changes and pressure differential), HEPA filter integrity testing, total particle counts under dynamic conditions, and a dynamic smoke pattern test for each PEC.

What ISO class does a compounding hood need?

The PEC must meet ISO Class 5 or better under dynamic operating conditions.

Is viable air sampling part of certification?

They're different. Certification covers non-viable items like particle counts, airflow and pressure. Viable air sampling for bacteria and fungi is also required at least every 6 months, and you can add it to the same quote request.

Which certification guide do certifiers use?

USP <797> points to the current CETA certification guide for sterile compounding facilities, or an equivalent guideline.