Biosafety Cabinet Certification Quotes
Biosafety cabinets (BSCs) are certified to NSF/ANSI 49. Tests typically include inflow and downflow velocity, HEPA filter leak testing, airflow smoke patterns and alarm checks. CDC's BMBL says cabinets should be certified at least annually, and after installation, moving or a filter change. Send one request to compare quotes.
Facilities anywhere in the U.S. can request quotes here.
What biosafety cabinet certification is
A biological safety cabinet (BSC) is a ventilated enclosure that uses directional airflow and HEPA filters to protect the user, the work and the room. Field certification checks that the cabinet still meets its performance criteria after installation or a period of use.
NSF/ANSI 49 is the U.S. standard for Class II cabinets. A typical field certification includes:
- Inflow velocity (for user protection)
- Downflow velocity (for product protection, Class II)
- HEPA filter leak testing of the supply and exhaust filters
- Airflow smoke pattern tests
- Site installation checks, including sash and alarm function
CDC's Biosafety in Microbiological and Biomedical Laboratories (BMBL, 6th edition) says BSCs should be certified at least annually, and whenever they are installed, moved, or have a filter changed or a repair that could affect containment.
When a BSC is used as a primary engineering control for sterile compounding, USP <797> also applies: the cabinet must meet ISO Class 5 under dynamic conditions and be recertified at least every 6 months. A Class II Type A2, B1 or B2 BSC used for hazardous drugs is a C-PEC under USP 800.
Who needs it
- Clinical, research and public-health labs that use Class I, II or III biosafety cabinets
- Pharmacies using a BSC as a PEC or C-PEC (often with USP 797 or USP 800 certification on the same visit)
- Any site that has just installed, relocated or had filters replaced in a cabinet
What to include in your quote request
- Facility address
- Number of cabinets, with class and type (I, II A2, II B2, III) and make/model if known
- Whether any cabinet is used for sterile compounding (USP <797>) or hazardous drugs (USP <800>)
- Whether you also want the room certified on the same visit
- Last certification date and due date
- Any institutional or BSL requirements the report should mention
Need quotes? Request quotes with one form →
Are you a certification or testing company? Join as a provider →
How getting quotes works here
- Send one request. Use the quote request form to describe your facility, where it is, the rooms or equipment, and the tests or standard you need.
- We share it with providers. Your request goes to certification and testing companies that cover your area and the type of work.
- Compare and choose. Providers that want the job send quotes. You compare scope and price side by side and pick who to hire, so you don't have to chase each company yourself.
Related services
- USP 797 certification
- USP 800 certification
- HEPA filter testing
- Fume hood testing
- Laminar flow hood certification
- Particle count testing
Requests are accepted nationwide. Browse locations.
FAQ
How often should a biosafety cabinet be certified?
At least annually, per CDC's BMBL. Also certify after installation, after the cabinet is moved, after a HEPA filter is replaced, and after any repair that could affect containment.
What standard is used?
NSF/ANSI 49 is the U.S. standard for Class II biosafety cabinet design and field certification. USP <797> also applies when a BSC is used as a PEC for sterile compounding.
What's the difference between Class I, II and III?
Class I protects the user and the room, but not the work. Class II (types A1, A2, B1, B2) protects the user, the work and the room, with different exhaust arrangements. Class III is a totally enclosed, gas-tight glove box.
Can a BSC used for hazardous drugs be certified under USP 800 too?
Yes. List it as a C-PEC in a USP 800 request, or add USP 800 rooms to a BSC request, so the same visit covers both.
Do I need to provide make and model?
It helps. The certifier uses the manufacturer's airflow set points. If you don't have them, include as much as you can (class, type, approximate size) and the certifier can often identify the cabinet on site.
Need quotes? Request quotes with one form →