Cleanroom Particle Count Testing Quotes

Cleanroom particle count testing measures airborne particles with a calibrated light-scattering particle counter at set sampling locations. Results are compared to ISO 14644-1 limits, for example 352,000 particles 0.5 µm and larger per cubic meter for ISO 7. It is the core test for ISO classification and USP <797> certification.

Facilities anywhere in the U.S. can request quotes here.

What particle count testing is

ISO 14644-1:2015 classifies air cleanliness by counting airborne particles at threshold sizes from 0.1 µm to 5 µm. Counts are cumulative: a 0.5 µm count includes every particle 0.5 µm and larger. Testers use light-scattering airborne particle counters, whose specifications are set by ISO 21501-4.

Key parts of a classification count:

  • Sampling locations: the minimum number comes from the room's area (ISO 14644-1, Table A.1). More can be added.
  • Particle sizes: one or more sizes are chosen for the class. 0.5 µm is the one size with a limit for every class from ISO 3 to ISO 9.
  • Occupancy state: as-built, at-rest or operational.
  • Limits: for ≥0.5 µm per m³, ISO 5 is 3,520, ISO 6 is 35,200, ISO 7 is 352,000 and ISO 8 is 3,520,000.

Particle counting is non-viable: it can't tell whether particles are living. Microbial (viable) air sampling is a separate test.

Who needs it

  • Cleanrooms being classified or periodically reclassified under ISO 14644-1 and ISO 14644-2
  • Sterile compounding pharmacies: USP <797> requires total particle count testing in all classified areas under dynamic conditions at least every 6 months
  • Facilities checking a room after construction, repairs or HVAC changes

What to include in your quote request

  • Facility address
  • Number of rooms or zones, the target ISO class and the area of each
  • Occupancy state to test (as-built, at-rest, operational)
  • Particle sizes you need reported, if your spec says
  • Whether this is a one-time classification or part of a recurring monitoring plan
  • Other tests for the same visit (HEPA leak, airflow, pressure, viable sampling)
  • Due date and report format

Need quotes? Request quotes with one form →

Are you a certification or testing company? Join as a provider →

How getting quotes works here

  1. Send one request. Use the quote request form to describe your facility, where it is, the rooms or equipment, and the tests or standard you need.
  2. We share it with providers. Your request goes to certification and testing companies that cover your area and the type of work.
  3. Compare and choose. Providers that want the job send quotes. You compare scope and price side by side and pick who to hire, so you don't have to chase each company yourself.

Related services

Requests are accepted nationwide. Browse locations.

FAQ

What particle sizes are counted for ISO classification?

ISO 14644-1 uses threshold sizes from 0.1 µm to 5 µm. You or your spec choose one or more sizes; 0.5 µm is the one size with a limit for every class from ISO 3 to ISO 9.

How many sampling locations does my cleanroom need?

ISO 14644-1:2015 Table A.1 sets the minimum number of sampling locations based on the room's floor area. Larger rooms need more locations.

Does particle counting detect bacteria?

No. Particle counters measure particle size and number, not whether particles are viable. Microbial air sampling is a separate test.

How often is particle count testing needed?

ISO 14644-2 calls for periodic classification annually unless risk assessment and monitoring data support longer. USP <797> requires total particle counts at least every 6 months.

Why does ISO 5 have no 5 µm limit?

ISO 14644-1:2015 dropped the 5 µm limit for ISO 5 because low counts of large particles make sampling statistically unreliable. Larger particles can be described with the M descriptor.