Cleanroom Environmental Monitoring Quotes (Viable Air and Surface Sampling)
Environmental monitoring checks a cleanroom for living microorganisms. USP <797> requires viable air sampling by impaction in every classified area at least every 6 months and surface sampling at least monthly for most compounding. Results are compared to action levels, such as more than 1 cfu per cubic meter of air in ISO 5.
Facilities anywhere in the U.S. can request quotes here.
What environmental monitoring is
Certification covers non-viable items like particle counts, airflow and pressure. Environmental monitoring covers viable (living) contamination: bacteria and fungi in the air and on surfaces.
USP <797> requirements:
- Viable air sampling: volumetric active air sampling with an impaction device, in each classified area (the ISO Class 5 PEC and ISO Class 7 and 8 rooms), under dynamic operating conditions, at least every 6 months
- Surface sampling: all classified areas and pass-through chambers, at least monthly for Category 1 and 2 compounding, at the end of compounding activity or a shift
- Category 3 compounding requires more frequent sampling
- Media and incubation: a general growth medium such as TSA, incubated to recover bacteria and fungi, with results recorded as colony-forming units (cfu)
USP <797> action levels:
| ISO class | Air (cfu per m³) | Surface (cfu per plate or swab) |
|---|---|---|
| ISO 5 | >1 | >3 |
| ISO 7 | >10 | >5 |
| ISO 8 | >100 | >50 |
If an action level is exceeded, USP <797> requires an attempt to identify the organism to the genus level and a documented corrective action.
Who needs it
- Sterile compounding pharmacies under USP <797> (and <825> radiopharmacies, which have their own sampling rules)
- Any cleanroom whose quality system requires microbial monitoring alongside ISO 14644 particle monitoring
- Facilities investigating a contamination event or an out-of-range result
What to include in your quote request
- Facility address
- Number of classified rooms and PECs, with their ISO classes
- Air sampling, surface sampling, or both, and how often (one-time, 6-month, monthly)
- Number of sample locations, if you have a sampling plan
- Whether you need lab identification of recovered organisms (to genus)
- Whether the same visit should include your 6-month USP <797> certification
- Report requirements
Need quotes? Request quotes with one form →
Are you a certification or testing company? Join as a provider →
How getting quotes works here
- Send one request. Use the quote request form to describe your facility, where it is, the rooms or equipment, and the tests or standard you need.
- We share it with providers. Your request goes to certification and testing companies that cover your area and the type of work.
- Compare and choose. Providers that want the job send quotes. You compare scope and price side by side and pick who to hire, so you don't have to chase each company yourself.
Related services
- USP 797 certification
- USP 825 radiopharmacy certification
- Particle count testing
- Cleanroom decontamination
- ISO 7 cleanroom
Requests are accepted nationwide. Browse locations.
FAQ
How often is viable air sampling required under USP 797?
At least every 6 months in each classified area, under dynamic operating conditions, using an impaction air sampler.
How often is surface sampling required under USP 797?
At least monthly for Category 1 and 2 compounding, in all classified areas and pass-through chambers, at the end of compounding activity or a shift. Category 3 requires more frequent sampling.
What are the USP 797 action levels for air sampling?
More than 1 cfu per cubic meter in ISO Class 5, more than 10 in ISO Class 7, and more than 100 in ISO Class 8.
Is environmental monitoring the same as certification?
No. Certification covers non-viable tests like particle counts, airflow and pressure. Environmental monitoring samples for living microorganisms. Many facilities schedule both together.
Can settling plates be used instead of an air sampler?
USP <797> requires volumetric active air sampling with an impaction device for viable air sampling.
Need quotes? Request quotes with one form →
Are you a certification or testing company? Join as a provider →